Sentinox
01SNX · Protect
Catch the cell that stops behaving like itself.
Thermal runaway shows faint signs first: a little extra heat, a voltage that sags too fast, self-discharge that drifts. Sentinox compares every cell to its twin and warns while there is still time.
Example One cell stops matching its twin.
02Capabilities
What Sentinox does.
01
Twin residuals
Warn on the gap between what a cell does and what its twin expects.
02
Edge first
Runs beside the BMS on Jetson-class hardware, offline if needed (planned).
03
Explained alerts
Every alert names the cell, the signal and the reason.
04
Fewer false alarms
Sensor faults are told apart from cell faults.
05
Escalation
From watch list to call-out, with your own rules.
06
Trained on rare events
Synthael supplies failure data the field cannot.
03Alert queue
What the team sees.
- SNX-2208Pack P-0412, cell 3-11Act nowΔT +4.2 °C, dV/dtrisk 0.92
- SNX-2211BESS rack 07, module 14WatchSelf-discharge driftrisk 0.61
- SNX-2197Bus 118, pack BWatchImpedance riserisk 0.55
- SNX-2215Pack P-0388, cell 1-04Act nowOff-gas sensor, ΔTrisk 0.88
- SNX-2190BESS rack 02, module 03ClearedRecovered after balancerisk 0.12
- SNX-2203Truck 41, pack AClearedSensor fault, not cellrisk 0.08
Example An alert queue for an example fleet and storage site. Assets and scores are made up.
04How it works
Step by step.
- 01
Watch
Track each cell’s temperature, voltage and self-discharge against the twin.
- 02
Score
Rate runaway risk from residuals and known precursors.
- 03
Warn
Raise an alert at the edge in under 100 ms (target).
- 04
Escalate
Hand to Cortova and your on-call team with a proposed action.
05Specification
The details.
| Item | Detail |
|---|---|
| Signals | Cell temperature and voltage, current, self-discharge, impedance; off-gas sensors if fitted |
| Latency | < 100 ms at the edge (target) |
| Hardware | NVIDIA Jetson; IGX for industrial sites (planned) |
| Training data | Field data plus Synthael simulations |
| Role | A second, earlier warning. Your BMS stays the protection layer. |
07Questions
Straight answers.
Does this replace our fire protection?
No. It adds early warning. Detection, suppression and your BMS protection stay in place.
How do you avoid alarm fatigue?
Alerts are graded, explained and separated from sensor faults. You set the thresholds.
Can it trip a contactor?
Not by default. It can request one through your BMS if you configure and approve that.
08Next step
Send one month of cycle data. Get one pack twin back.
Export a month of BMS telemetry from a few packs. We return a calibrated twin, a state-of-health and remaining-life estimate per pack, and the three cells we would watch first.